Attic Ventilation Requirements Ontario
Vent requirements 1 except as provided in sentence 2 the unobstructed vent area shall be not less than 1 300 of the insulated ceiling area.
Attic ventilation requirements ontario. Live work units shall be mechanically ventilated in accordance with the requirements of sentence 1. Air vent recommends 1 square foot of ventilation for every 150 square feet of attic floor space with half the ventilation represented by intake vents and half by exhaust vents such as ridge vents. The following product options will allow you to achieve an intake nfva of 528 square inches. These types of roofs therefore require more ventilation than common attic type roofs.
Of net free area of intake needed at or near the soffit. The ontario building code vent requirements 9 19 1 2. Self contained mechanical ventilation systems serving only one dwelling unit shall conform to note. Vents are rated by their net free area or the amount of space for air to flow in or out.
Choose one of the following products to meet the recommended intake nfva of 528 square inches. However in canada the largest contributor to infiltration is the temperature difference between the inside of the house and the outside causing in a phenomenon called stack effect. Allows cool dry air to enter the attic. For the 1 150 attic ventilation requirement simply double the amount of exhaust and intake calculated.
How to correct inadequate attic venting to stop attic condensation ice dam leaks attic mold roof structure damage advice on omitting gable end vents when soffit and ridge venting are installed how to detect roof venting deficiencies attic insulation defects and attic condensation problems best construction practices. Attic ventilation works on the principle that heated air naturally rises primarily utilizing two types of vents. Of net free area of exhaust needed at or near the ridge. As ventilation rates vary with wind speed and direction the magnitude of natural ventilation is difficult to predict.
The ontario building code required ventilation. How to correct improper or inadequate attic or under roof ventilation. You can calculate attic ventilation requirements by determining the square footage of your attic floor its width times its length and compare that to the total required net free area nfa. Ridge static attic vents 384 00 minimum sq.
For minimum building code requirements use the 1 300 ratio instead of the 1 150 ratio. This helps make it easy to calculate how many vents you. On july 1.