Attic Fan Ductwork
The attic ductwork is flex duct work.
Attic fan ductwork. Which direction is better. This american designed fan is designed to reduce attic temperatures and remove destructive moisture thus making your home more comfortable and reducing the load on your hvac system and lowering your electricity bills. This setup requires an in line centrifugal fan mounted in the attic drawing air simultaneously from both bathrooms see photo. Much of that heat then conducts downward and finds its way into the house.
Throw duct leakage into the mix and the problems are even worse. In all cases the ducting needs to conduct the exhaust to the building exterior and needs to terminate in an animal proof vent cover. Meticulously seal seams and add reflective insulation around your ductwork convert your attic to a conditioned space. This article describes routing bath exhaust fan duct upwards through an attic or roof space or downwards through a floor or crawl space.
Jim asks is it ok to have a bath exhaust fan vent into my attic no it s never a good idea to have any exhaust fan in your home dump all that hot moist air in your attic. A grille in each bathroom attaches to ducts which then fasten to a y connector at the fan. When bathroom exhaust ducts are not properly insulated and vented the warm moist air traveling through them hits the colder section of the duct in the unconditioned attic space causing condensation on the duct work. With hundreds of square feet of ductwork surface area in the attic and a δt of 75 f the air coming out of the vents in your home will be significantly higher than 55 f.
Trying to solve the heat gain problem in your attic by using a fan is like lying out at the beach with a fan blowing over you and thinking you re not going to get a sunburn. If you have ductwork furnaces air conditioners water heaters water piping etc. It was new when the ac was put in 7 years ago. That condensation drips from the duct work in the attic space and the exhaust fan.
This is much easier to do if you have attic access because if you don t you usually have to remove some ceiling drywall and run the ducts along a joist. In your attic it would be a good consideration to. The building code requires a bathroom exhaust fan to vent outside the building so installation of a new bathroom fan necessarily involves installation of ductwork. It can cause you a lot of problems with mold and mildew forming on the underside of your rafters and decking as well as getting into your insulation.
Move the ducting and equipment to the crawlspace or the interior of your home.